Challenges

The original ICNIRP 2020 RF standard distinguishes basic restrictions (e.g., 100 kHz–6 GHz, general-public whole-body SAR 0.08 W/kg averaged 30 min; local head/torso SAR 2 W/kg over 10 g averaged 6 min) from external reference levels (e.g., >2 GHz whole-body incident 10 W/m² averaged 30 min and >2–6 GHz local reference 40 W/m² averaged 6 min). These are different metrics/averaging scenarios and neither a consumer alarm nor direct proof of disease.